WebType X gypsum wallboard, 5/8" in thickness (“5/8" Type X wallboard”), is manufactured for use as one component of an assembly/system (such as a wall) where a fire resistance rating is required in a residential, … WebStep 1. Double the number of Type X sheets on the wall for a simple system installed over fire-resistant fiberglass insulation; each sheet of 5/8-inch Type X drywall is rated to …

CertainTeed Type X Fire-Resistant Drywall Panel - 5/8-in x …

Webo Fire Resistance – Impact-Resistant Gypsum Panels are made with a non-combustible Type X core and are UL-classified for use in any fire-rated assembly where a 5/8” Type X panel is approved. Refer to GA-600 Fire Resistance and Sound Control Design Manual. Consult with gypsum manufacturer for specific recommendations. WebOct 30, 2016 · Also the type of gypsum panel used Type X board or Type C board. Fire code C has a better rating than Type X. To include the installation of the board joints Two layers of 1/2 inch require the first … ial wlf https://digitalpipeline.net

CTG-2337 Type X DS V1 - CertainTeed

WebCertainTeed Type X Gypsum Board has a Flame Spread rating of 15 and Smoke Developed rating of 0, in accordance with ASTM E84, (UL 723, UBC 8-1, NFPA 255, CAN/ULC-S102). Fire Resistance Fire resistance tests are conducted in accordance with ASTM E 119, (ANSI/UL 263, UBC 7-1, NFPA 251, CAN/ULC-S101) and no warranty is … Webangles to the framing and attached with 1-5/8” (41 mm) Type S or S-12 drywall screws (for steel framing) or 2-3/8” (60 mm) nails or 1-7/8” (48 mm) Type W or S drywall screws (for … Webangles to the framing and attached with 1-5/8” (41 mm) Type S or S-12 drywall screws (for steel framing) or 2-3/8” (60 mm) nails or 1-7/8” (48 mm) Type W or S drywall screws (for wood framing) spaced 8” (203 mm) o.c. Joints of the face layer are offset 24” (610 mm) from the joints in the base layer. Face layer joints and fasteners are mombasa port website

code compliance - When hanging a double layer of drywall, do …

Category:SOUND-RATED PARTITIONS AND FLOOR-CEILING …

Tags:Fire rating of 2 layers 5/8 type x

Fire rating of 2 layers 5/8 type x

How many layers of gypsum are needed for a 1 hour rating?

Weband double-layer 5/8-in. Sheetrock Brand Firecode ‘C’ panels. to allow it to survive for 57 minutes, C had successfully resisted failure at which time it developed a largetwice as long as Type X, 10 times a gypsum wallboard panel vastly crack and began to fail. superior to Type X fire-rated boards. longer than regular 5/8-inch board. Type C ... WebJun 10, 2016 · It contains the most used gypsum fire rated designs and it also contains information on sound ratings for most of the assemblies. Plus it is a free download which the others are not. The main note is that you …

Fire rating of 2 layers 5/8 type x

Did you know?

WebThickness: 1/2" (12.7 mm) / 5/8" (15.9 mm) Width: 4' (1220 mm) standard Length: 8' to 12' standard (2440 mm to 3660 mm) Weight (nominal): 1/2" (12.7 mm) – 1.9 psf (9.3 kg/m2) 5/8" (15.9 mm) – 2.3 psf (11.2 kg/m2) … Web*note: single layer of 5/8” type “x” drywall for 1 hour fire rating, 2 layers for 2 hour *note: single layer of 5/8” type “x” drywall for 1 hour fire rating, 2 layers for 2 hour ... 8" type "x" drywall for 1 hour fire rating ct stud 5/8" type "x" drywall 1" shaft liner fas j-track 3 8" nominal gap (3 4" joint protection) www ...

WebSheetrock® Brand Firecode® C Gypsum Panels Item: 142310 Sheetrock® Brand Firecode® C Panels Enhanced proprietary Type X panels for interior wall and ceiling applications Key Documents & Design Files Submittal Sheet PDF 428.4 KB Installation Guides Architectural Specifications DOCX 71.2 KB Available Product Options Thickness: … WebJul 30, 2007 · (2) layers of 5/8" fire rated drywall Type X (not 1/2") Most townships just follow the single layer rule, but I've worked in townships where the double layer is required. I guess it would depend on where you are working. IRC 2006 Section r309.2

Web1 hr. Stag Wd Stud—5/8 SHEETROCK Brand gypsum panels, 45 G FIRECODE C core—2 x 4 24 o.c. max on ea side 2 x 6 com plate—panels att with 6d ctd nails or 1-7/8 screws … WebSheetrock® Brand Firecode® X Panels The original 5/8 in. (15.9 mm) Type X panels for interior wall and ceiling applications Key Documents & Design Files Submittal Sheet PDF 334.2 KB Installation Guides Architectural …

WebFire Rating Firecode® ASTM Type ASTM C635 Sustainability Recycled Content 45.3% Physical Data Edge DGW - Drywall Suspension Panel Size 1.5 in. x 8 ft. Material HDG Steel Warranty Warranty USG Ceilings Commercial Application Warranty (English) - SC2102 PDF 146 KB Installation Installation Guide play

WebUL Design U360 is a 2-hour, load-bearing firewall tested by UL that needs only three layers of 5/8″ type X gypsum board resulting in savings of 25% on drywall labor and materials. Sound-absorbing UL design U369 has a high STC rating of 58 making it the design choice for sound control. ialy andriamparanonyWebGypsum Wallboard (each side) Finish Insulation STC Fire Rating ½”, one layer one side none 39 NR 5/8” type X, one layer one side none 39 1 hr. 5/8” type X, one layer one side 3 ½” – 4” fiberglass batt 50 1 hr. ... 5/8” type X, two layers each side two each side none 52 2 hr. 5/8” type X, two layers each side two each side 3 ½ ... ialys rubyol creamWebHow do I achieve a fire rating? Use UL design W419 for 1- through 4-hour shaftwall systems or UL design V497 for 1- and 2-hour assemblies using Type X gypsum board … mombasa teachers saccoWeb*note: single layer of 5/8” type “x” drywall for 1 hour fire rating, 2 layers for 2 hour *note: single layer of 5/8” type “x” drywall for 1 hour fire rating, 2 layers for 2 hour ... note: single layer of 5 8" type "x" drywall for 1 hour fire rating deflection drift angle dda-1** (both sides) 1 2" nominal joint (1" joint protection ... ialyssos pronunciationWebCommon Measurement (W x L) 4-ft x 8-ft Common Thickness in Inches 5/8-in Core Type Type X Fire Resistant Yes For Use in Ceilings Yes For Use in Garages Yes Item … ial wplWebNov 16, 2024 · Trying to find the fire rating/UL assembly of a 3 1/2″ TnG roof decking that is on a 1950’s school. I keep strikuing out on the web and in the UL book any help would be appreciated. ... a layer of 5/8″ type X will give you 40 minutes. So, your suggested assembly would actually add up to 60 minutes, but you need the 5/8″ sheathing for ... mombasa road traffic update todayWebTwo layers of gypsum board is generally used for two hour fire wall protection. The protection (and rating) comes from the proper installation, including proper nailing for … ial wrexham